韩国_KFPA_火灾统计年报_화재조사보고서
8
2010
KOREAN FIRE DATA
2010KOREAN FIRE DATA
December 2011
FOREWORD
We are pleased to issue the revised edition of the English booklet entitled "Korean Fire Data" which offers an outline of Korean fire statistics during the year 2010 and fire cases in 2010.
The first edition was published in 1997 in accordance with the "The agreement of cooperation between NFPA (National Fire Protection Association) and KFPA (Korean Fire Protection Association)." It was probably the first Korean fire related statistics in English which made the way for disseminating of information throughout the world including USA. Since then, the revised editions have been issued annually.
In year 2007 the renovation of nationwide fire incident statistics, 「Korea National Fire Incident Classification System」, had gone into effect, therefore numbers of fire incidents in fire statistics has increased because the new statistics began to include fires with no property loss. Also the Classification rule has been changed since 2007.
In year 2010, fires were decreased by - 11.5%(-5,455 fires) in numbers, civilian death toll by - 25.7%(-105), civilian injuries by - 21.9%(-444), and property loss by +5.9%.
Most severe fire incident was at a nursing home which ended up with 10 deaths and 17 injuries. Also there was a fire in a high-rise condominium which ended up with 7 injuries and 5.7 billion won. You can see the fire reports for these cases.
We hope this document serves not only to deliver the current Korean fire data but to reduce fire disasters globally.
Acknowledgements
The KFPA gratefully thanks fire departments, National Emergency Management Agency and National fire data system for these precious data.
For more information about the Korean Fire Protection Association, visit www.kfpa.or.kr or call 82-2-3780-0322.
Copies of this report are available from:
Korean Fire Protection Association.
Research & Investigation team
35-4, Yeouido-dong, Yeungdeunpo-gu. Seoul, Republic of Korea www.kfpa.or.kr
e-mail: hryu@kfpa.or.kr
phone: 82-2-3780-0322
Copyright © 2011, Korean Fire Protection Association.
CONTENTS
■ FIRE LOSS IN KOREA
-Overview in 2010 2
-Fire experience Anays 9
-Fire trend 18
-International comparison 24
☐ Fire Investigation Reports
-Fire in a nursing home 31
-Fire in a high-rise complex residential building 42
$\blacksquare$ Appendix 49
- Fire Loss in the Republic of Korea, 1948-2010
FIRE LOSS IN KOREA
Source : 'Fire Statistics Yearbook 2010'
by the National Emergency Management Agency of the Republic of Korea
Overview
I. Overview of 2010 Korea Fire Experience
| 2010 | 2009 | Change in number | Change in percentage | |
|---|---|---|---|---|
| No. of Fires | 41,863 | 47,318 | -5,455 | -11.5 |
| Deaths* | 304 | 409 | -105 | -25.7 |
| Injuries | 1,588 | 2,032 | -444 | -21.9 |
| Property Loss (⌫ million) | 266,776 | 251,853 | 14,923 | +5.9 |
※ Note :1. 1,130 KRW is worth 1 USD(as of Dec 1, 2011) approximately, the same shall apply hereinafter.
- The Property loss values in this report are not adjusted for inflation hereinafter.
- Casualties include civilians and fire fighters.
- Death after 72 hours or less by the injury from fire.
〔图〕插图
41,863 fires were reported in Korea during 2010.
○ down 11.5% from 2009
○ 304 fire deaths
○ 1,588 fire injuries
○ ¥ 266 billion in property damage, up5.9% from 2009
10,509 fires were reported in Residential structure.
○ down 10.7% from 2009
○ 199 fire deaths
○ 749 fire injuries
○ ¥ 53 billion in property damage
5,788 fires were reported in transportation(vehicle, train, ship, aircraft)
○ 18 fire deaths
○ 109 fire injuries
○ 23.8 billion in property damage
2,209 fires were reported in wildland.
○ 5 fire deaths
○ 24 fire injuries
○ ¥ 1.4 billion in property damage
II. Fires and Property Loss by type
| Type | Fire | Fire | Property loss1,2(¥) | Property loss1,2(¥) | Death | Injury |
|---|---|---|---|---|---|---|
| Type | No. | Percent change from 2009 | ¥ | Percent change from 2009 | Death | Injury |
| Total | 41,863 | -11.5 | 266,776,332 | 5.9 | 304 | 1,588 |
| Residential | 10,509 | -10.7 | 53,768,644 | 8.0 | 199 | 749 |
| Non-residential | 16,395 | -0.5 | 174,378,854 | 3.5 | 76 | 622 |
| Vehicle, train | 5,788 | -3.3 | 23,797,217 | -1.5 | 18 | 109 |
| Explosive, Gas industry | 30 | -40.0 | 777,147 | 12.0 | 1 | 15 |
| Ship, aircraft | 112 | -20.0 | 8,843,930 | 427.9 | 0 | 9 |
| Wildland | 2,209 | -47.1 | 1,457,022 | -52.2 | 5 | 24 |
| Others | 6,820 | -21.8 | 3,753,518 | -7.3 | 5 | 60 |
$^{1}$ No adjustment was made for inflation in the year-to-year comparison.
$^{2}$ This includes overall direct property loss to contents, structure, a vehicle, machinery, vegetation or anything else involved in a fire. It does not include indirect losses, e.g., business interruption or temporary shelter costs.
〔图〕插图
Percentage(No. of fires)
〔图〕插图
Percentage(Property loss)
Ⅲ. Fires by causes
〔图〕插图
| Cause | No. | Death | Injury | Casualty /fire | Property loss | loss/fire |
|---|---|---|---|---|---|---|
| Total | 41,863 | 304 | 1,588 | 0.05 | 266,776,332 | 6,372.60 |
| Gas (explosion) | 184 | 5 | 106 | 0.6 | 1,794,674 | 9,753.70 |
| Chemical | 288 | 0 | 28 | 0.1 | 4,698,075 | 16,312.80 |
| By nature | 377 | 0 | 0 | 0 | 1,709,715 | 4,535.10 |
| Car accident | 567 | 8 | 21 | 0.05 | 3,791,317 | 6,686.60 |
| Arson | 632 | 53 | 130 | 0.29 | 4,245,609 | 6,717.70 |
| Others | 807 | 4 | 51 | 0.07 | 5,892,610 | 7,301.90 |
| Arson (suspicious) | 2,043 | 27 | 92 | 0.06 | 8,746,627 | 4,281.30 |
| Mechanical | 4,060 | 3 | 70 | 0.02 | 23,245,995 | 5,725.60 |
| Unkown | 4,209 | 102 | 317 | 0.1 | 106,035,112 | 25,192.50 |
| Electrical | 10,827 | 48 | 225 | 0.03 | 66,383,201 | 6,131.30 |
| Human error | 17,869 | 54 | 548 | 0.03 | 40,233,397 | 2,251.60 |
IV. Fires by time
〔图〕插图
| Time | No. of Fires | Deaths | Injuries | Property loss |
|---|---|---|---|---|
| total | 41,863 | 304 | 1,588 | 266,776,332 |
| 0~1 | 1,476 | 16 | 74 | 11,479,339 |
| 1~2 | 1,462 | 21 | 56 | 14,720,023 |
| 2~3 | 1,313 | 17 | 76 | 13,568,205 |
| 3~4 | 1,239 | 25 | 54 | 12,150,123 |
| 4~5 | 1,120 | 21 | 56 | 11,815,753 |
| 5~6 | 1,038 | 14 | 38 | 8,416,720 |
| 6~7 | 1,034 | 6 | 44 | 9,842,448 |
| 7~8 | 1,082 | 7 | 38 | 7,779,666 |
| 8~9 | 1,356 | 6 | 55 | 8,322,035 |
| 9~10 | 1,597 | 6 | 62 | 9,216,552 |
| 10~11 | 1,894 | 6 | 69 | 11,641,478 |
| 11~12 | 2,040 | 9 | 107 | 19,340,236 |
| 12~13 | 2,232 | 12 | 85 | 11,216,310 |
| 13~14 | 2,427 | 7 | 74 | 11,018,432 |
| 14~15 | 2,481 | 9 | 89 | 11,606,722 |
| 15~16 | 2,417 | 6 | 73 | 9,857,569 |
| 16~17 | 2,329 | 18 | 106 | 10,136,672 |
| 17~18 | 2,145 | 16 | 60 | 6,989,603 |
| 18~19 | 2,205 | 20 | 71 | 11,504,628 |
| 19~20 | 2,086 | 19 | 68 | 10,902,335 |
| 20~21 | 1,891 | 5 | 65 | 12,619,913 |
| 21~22 | 1,746 | 16 | 42 | 9,156,314 |
| 22~23 | 1,678 | 7 | 54 | 13,962,075 |
| 23~24 | 1,575 | 15 | 72 | 9,513,181 |
V. Causes in Residential Occupancy
〔图〕插图
| Cause | No. fires | Death | Injury | property loss |
|---|---|---|---|---|
| Total | 10,509 | 199 | 749 | 53,768,644 |
| Electrical | 2,388 | 29 | 111 | 18,451,976 |
| Mechanical | 487 | 0 | 12 | 2,337,779 |
| Gas Explosion | 71 | 4 | 51 | 612,395 |
| Chemical | 19 | 0 | 2 | 2,389,037 |
| Human error | 5,214 | 37 | 247 | 12,198,816 |
| Natural | 120 | 0 | 0 | 478,510 |
| others | 161 | 3 | 12 | 822,029 |
| Unkown | 1,172 | 73 | 187 | 12,437,783 |
| Arson | 305 | 33 | 71 | 1,767,697 |
| Arson (suspicious) | 572 | 20 | 56 | 2,272,622 |
Firstly, Human error accounted for a half of home fires. Secondly, Causes from Electricity (electrical failure or malfunction) accounted for 23%. Human factors are Abandoned or discarded material, Heat source too close, Playing with heat source and so on.
Fire experience analysis
I. Fire experience during 2001-2010
〔图〕插图
| Year | No. fires | Death | Injury | Property loss (billion won) |
|---|---|---|---|---|
| 2001 | 36,169 | 516 | 1,860 | 169.8 |
| 2002 | 32,966 | 491 | 1,744 | 143.4 |
| 2003* | 31,372 | 744 | 2,089 | 151.6 |
| 2004 | 32,737 | 484 | 1,820 | 146.6 |
| 2005 | 32,340 | 505 | 1,837 | 171.4 |
| 2006 | 31,778 | 446 | 1,734 | 150.8 |
| 2007** | 47,882 | 424 | 2,035 | 248.4 |
| 2008 | 49,631 | 468 | 2,248 | 383.1 |
| 2009 | 47,318 | 409 | 2,035 | 251.9 |
| 2010 | 41,863 | 304 | 1,588 | 266.8 |
- In 2003, Dague subway arson fire resulted in 192 deaths.
**Since 2007, No. of fires uprised because fires with no loss has been sumed.
II. Fires by Property type, 2007*-2010
〔图〕插图
| Type | 2007 | 2008 | 2009 | 2010 |
|---|---|---|---|---|
| Complex | 495 | 437 | 412 | 432 |
| Cultural asset | 6 | 8 | 4 | 7 |
| Educational | 478 | 534 | 468 | 471 |
| Health care | 397 | 458 | 404 | 404 |
| Industrial | 5,500 | 5,677 | 5,306 | 5,384 |
| Mercantile, office | 6,924 | 7,626 | 7,259 | 7,160 |
| others | 11,964 | 11,685 | 11,107 | 9,091 |
| Residential | 11,430 | 12,283 | 11,767 | 10,509 |
| ship, aircraft | 129 | 127 | 140 | 112 |
| Transportation facility | 211 | 323 | 289 | 296 |
| vehicle, train | 6,220 | 6,449 | 5,983 | 5,788 |
| wildland | 4,128 | 4,024 | 4,179 | 2,209 |
*In year 2007 the renovation of nationwide fire incident statistics,「Korea National Fire Incident Classification System」, had gone into effect, therefore this report analyzes occupancy fire trend since 2007.
Ⅲ. Residential (Houses & apartment), 2007~2010
〔图〕插图
| Year | No. fires | Death | Injury | Property loss (¥thousand) |
|---|---|---|---|---|
| 2010 | 10,509 | 199 | 749 | 53,768,644 |
| 2009 | 11,767 | 226 | 854 | 49,792,818 |
| 2008 | 12,283 | 220 | 917 | 50,070,305 |
| 2007 | 11,430 | 233 | 833 | 45,062,377 |
In all, fires in the residentila occupancy fires (one- and two-family homes including apartments) resulted in 199 civilian deaths, 65.4% of all death in 2010. However, home fire deaths decreased steadily.
IV. Fires by Industry classification, 2007-2010
〔图〕插图
| Industry | No | Fire | Injury | Property loss (thousand won) | loss/a fire |
|---|---|---|---|---|---|
| Total | 10,363 | 54 | 663 | 257,413,716 | 24,839.70 |
| Printing | 177 | 0 | 14 | 3,560,506 | 20,115.90 |
| Machinery | 3,068 | 12 | 163 | 34,863,769 | 11,363.70 |
| Ceramic | 154 | 0 | 5 | 1,988,834 | 12,914.50 |
| Electric | 580 | 2 | 66 | 20,133,197 | 34,712.40 |
| Chemical | 756 | 4 | 90 | 39,925,107 | 52,811.00 |
| Mining | 41 | 0 | 3 | 355,782 | 8,677.60 |
| Petrochemical | 95 | 2 | 33 | 6,058,342 | 63,772.00 |
| Pulp&Paper | 235 | 0 | 7 | 8,632,576 | 36,734.40 |
| Food | 603 | 7 | 26 | 14,514,184 | 24,070.00 |
| Others | 3,037 | 21 | 212 | 88,574,929 | 29,165.30 |
| Textile | 930 | 5 | 24 | 25,646,724 | 27,577.10 |
| Wood processing | 687 | 1 | 20 | 13,159,766 | 19,155.40 |
〔图〕插图
Property loss per fire by industry
Korea fire departments were reported to 10,363 fires in industrial and manufacturing properties in 2007-2010.
Property loss per fire is highest in Petrochemical industry.
V. Arson, 2007-2010
〔图〕插图 No of Arson fire by type, 2007-2010.
| Type | 2010 | 2009 | 2008 | 2007 |
|---|---|---|---|---|
| Structure | 1,592 | 1,748 | 2,315 | 1,787 |
| Vehicle, train | 588 | 829 | 1,003 | 699 |
| wildland | 68 | 164 | 149 | 76 |
| others | 422 | 611 | 770 | 530 |
*: including fires by suspicion of arson
During 2007~2010, 13,351 intentional fires were reported to fire departments. These fires were associated with losses of 347 fire deaths, 1,110 fire injuries.
〔图〕插图
Casualties by Arson(2007~2010)
〔图〕插图
Arson fire No. by Arsonist's age group.(excluding Unknown cases)2007-2010
In 2007~2010, over 70% of Known arson fires were by over the age of 40.
〔图〕插图
Motive of arson, 2007~2010
| Motive | Residential | Non-residential | Vehicle | Total |
|---|---|---|---|---|
| Total | 3,933 | 3,509 | 3,119 | 12,894 |
| Unknown | 1,739 | 2,051 | 2,024 | 7,366 |
| Others | 523 | 535 | 398 | 1746 |
| Accidental | 364 | 345 | 264 | 1211 |
| Family trouble | 493 | 67 | 40 | 618 |
| Disatisfaction | 202 | 162 | 126 | 576 |
| Mental disorder | 202 | 51 | 15 | 289 |
| Suicide | 139 | 40 | 44 | 238 |
| Fire | 125 | 64 | 23 | 232 |
| Crime concealment | 49 | 30 | 86 | 170 |
| Revenge | 15 | 51 | 14 | 97 |
| Antagonism to Community | 9 | 20 | 18 | 60 |
| Liability | 11 | 28 | 7 | 50 |
| Protest | 0 | 11 | 17 | 50 |
| Insurance swindle | 0 | 6 | 1 | 7 |
Fire trend
I. Fire experience, 1960~2010
〔图〕插图
Fire trend in No of fire, 1960~2010
| Year | No. of fire | No. of fires per 100 thousand population |
|---|---|---|
| 1960 | 1,946 | 7.8 |
| 1966 | 3,077 | 10.6 |
| 1970 | 4,969 | 16.1 |
| 1975 | 4,259 | 12.3 |
| 1980 | 5,438 | 14.5 |
| 1985 | 8,137 | 20.1 |
| 1990 | 14,249 | 32.8 |
| 1995 | 26,071 | 58.4 |
| 2000 | 34,844 | 75.5 |
| 2005 | 32,340 | 68.4 |
| 2010 | 41,863 | 86.2 |
For the 1960-2010 period, the number of Fires per 100 thousand population has ranged from a low of 7.8 in 1960 to 86.2 in 2010 for an overall increase of 1,030%. There was consistent pattern going up until 2005.
II. Death and Injury by Fires, 1960-2010
〔图〕插图
| Year | Death | Injury | No. of casualty per 100 thousand population |
|---|---|---|---|
| 1960 | 180 | 287 | 1.9 |
| 1966 | 165 | 343 | 1.7 |
| 1970 | 294 | 830 | 3.6 |
| 1975 | 219 | 710 | 2.7 |
| 1980 | 247 | 641 | 2.4 |
| 1985 | 260 | 820 | 2.7 |
| 1990 | 348 | 1200 | 3.6 |
| 1995 | 571 | 1648 | 5.0 |
| 2000 | 531 | 1853 | 5.2 |
| 2005 | 505 | 1837 | 5.0 |
| 2010 | 304 | 1588 | 3.9 |
For the 1960-2010 period, the number of civilian injuries per 100 thousand population has ranged from a low of 1.9 in 1960 to 3.9 in 2010 for an overall increase of 105%. There was consistent pattern going up until 2005.
Ⅲ. Fire Death by Age, 1983-2010
〔图〕插图
| Age | No. of death** | Age | No. of death |
|---|---|---|---|
| 0-4 | 1,192 | 50 - 54 | 970 |
| 5-9 | 611 | 55 - 59 | 805 |
| 10-14 | 413 | 60 - 64 | 770 |
| 15 - 19 | 869 | 65 - 69 | 710 |
| 20 - 24 | 1,130 | 70 - 74 | 707 |
| 25 - 29 | 1,405 | 75 - 79 | 676 |
| 30 - 34 | 1,406 | 80 - 84 | 320 |
| 35 - 39 | 1,466 | 85 - 89 | 163 |
| 40 - 44 | 1,227 | 90~ | 66 |
| 45 - 49 | 1,122 | Total | 16028 |
*Source from Bureau of statistics
**Death Data from Bureau of statistics are a little different from the data of NEMA.
IV. Fire experience by Age group, 1983~2010
〔图〕插图 Trend, Fire death by age group, Youth(~15), Middle(15~64), Old(65~ )
Population of 65 or more account for 11% of total population, but 37% for death by fire.
| Age 65 or more population | 1960 | 1970 | 1980 | 1990 | 2000 | 2010 |
|---|---|---|---|---|---|---|
| % | 2.9 | 3.1 | 3.8 | 5.1 | 7.2 | 11 |
No. of fire death, 1983-2010
| AgeYear | ~14 | 15 ~ 64 | 65~ | Total |
|---|---|---|---|---|
| 1983 | 209 | 356 | 35 | 601 |
| 1984 | 167 | 414 | 52 | 636 |
| 1985 | 103 | 347 | 46 | 497 |
| 1986 | 129 | 426 | 52 | 607 |
| 1987 | 115 | 392 | 54 | 561 |
| 1988 | 118 | 487 | 68 | 673 |
| 1989 | 114 | 535 | 88 | 737 |
| 1990 | 75 | 428 | 82 | 585 |
| 1991 | 79 | 412 | 70 | 563 |
| 1992 | 87 | 551 | 117 | 755 |
| 1993 | 103 | 640 | 142 | 885 |
| 1994 | 106 | 552 | 146 | 804 |
| 1995 | 100 | 599 | 157 | 856 |
| 1996 | 89 | 587 | 141 | 817 |
| 1997 | 93 | 562 | 140 | 795 |
| 1998 | 61 | 420 | 113 | 594 |
| 1999 | 84 | 450 | 120 | 654 |
| 2000 | 40 | 408 | 148 | 596 |
| 2001 | 73 | 396 | 138 | 607 |
| 2002 | 54 | 349 | 152 | 555 |
| 2003 | 63 | 447 | 180 | 690 |
| 2004 | 42 | 198 | 132 | 372 |
| 2005 | 19 | 270 | 154 | 443 |
| 2006 | 42 | 241 | 117 | 400 |
| 2007 | 7 | 199 | 109 | 315 |
| 2008 | 19 | 204 | 97 | 320 |
| 2009 | 10 | 137 | 83 | 230 |
| 2010 | 15 | 163 | 101 | 279 |
International comparison
I. Fire experience, US and Korea
〔图〕插图
Fire Death per Million population, US vs. Korea
〔图〕插图
No of fire per Million population, US vs. Korea
For fire death per population, There was consistent pattern going down in USA. In Korea, there was slight pattern going up until 2005.
| Year | USA* | USA* | Republic of Korea | Republic of Korea |
|---|---|---|---|---|
| Year | Fire Deaths per Million Population | Fire per thousand Population | Fire Deaths per Million Population | Fire per thousand Population |
| 1977 | 33.6 | 14.8 | 7.2 | 0.1 |
| 1978 | 34.6 | 12.7 | 6.5 | 0.2 |
| 1979 | 33.7 | 12.6 | 7.7 | 0.2 |
| 1980 | 28.6 | 13.1 | 6.6 | 0.1 |
| 1981 | 29.1 | 12.6 | 7.7 | 0.2 |
| 1982 | 25.9 | 10.9 | 7.1 | 0.2 |
| 1983 | 25.3 | 9.9 | 9.7 | 0.2 |
| 1984 | 22.2 | 9.9 | 9.3 | 0.2 |
| 1985 | 25.9 | 9.9 | 6.4 | 0.2 |
| 1986 | 24.3 | 9.4 | 7.5 | 0.2 |
| 1987 | 23.9 | 9.6 | 7.7 | 0.2 |
| 1988 | 25.4 | 9.9 | 9.8 | 0.3 |
| 1989 | 21.9 | 8.6 | 10.4 | 0.3 |
| 1990 | 20.8 | 8.1 | 8.0 | 0.3 |
| 1991 | 17.6 | 8.1 | 12.0 | 0.4 |
| 1992 | 18.4 | 7.6 | 11.6 | 0.4 |
| 1993 | 17.8 | 7.5 | 13.0 | 0.4 |
| 1994 | 16.2 | 7.8 | 12.5 | 0.5 |
| 1995 | 17.2 | 7.4 | 12.8 | 0.6 |
| 1996 | 18.5 | 7.3 | 13.1 | 0.6 |
| 1997 | 14.8 | 6.6 | 12.5 | 0.7 |
| 1998 | 14.6 | 6.4 | 11.1 | 0.7 |
| 1999 | 12.8 | 6.5 | 11.9 | 0.7 |
| 2000 | 14.3 | 6.0 | 11.5 | 0.8 |
| 2001 | 21.7 | 6.1 | 11.1 | 0.8 |
| 2002 | 11.7 | 5.8 | 10.5 | 0.7 |
| 2003 | 13.5 | 5.5 | 15.9 | 0.7 |
| 2004 | 13.3 | 5.3 | 10.3 | 0.7 |
| 2005 | 12.4 | 5.4 | 10.7 | 0.7 |
| 2006 | 10.9 | 5.5 | 9.4 | 0.7 |
| 2007 | 11.4 | 5.2 | 8.9 | 1.0 |
| 2008 | 10.9 | 4.8 | 9.7 | 1.0 |
| 2009 | 9.8 | 4.4 | 8.5 | 1.0 |
| 2010 | 10.1 | 4.3 | 6.3 | 0.9 |
*Source: FIRE LOSS IN THE UNITED STATES DURING 2010 by NFPA
Fire Deaths Around the World, per Million Population, 1993 - 2002*
〔图〕插图 *Source: CTIF Center of Fire Statistics, Fire Statistics, No. 10, 2004, Table 5
No. of fires per 1000 population Around the World, 2004
〔图〕插图 Source: Centre of Fire Statistics of CTIF - World Fire Statistics 2006 - Report No. 11, Fig.2)
FIRE INVESTIGATION REPORT
Fire in a nursing home
Fire in a nursing home
General Information
○ Date and time of Fire: About 04:10 AM, 12 Nov. 2010, Friday
○ Structure: Steel-concrete slabs, One building, Two-story
○ Casualty: Death 10, Injured 17 (including serious dementia and stroke patients, etc.)
○ Room of ignition: Office on the first floor
○ Point of origin: Around the panel board in the office on the first floor.
○ Ignition source: Electric fault (suspicious)
II Building detail
○ Building permission
The nursing home for the Aged owned by Pohang-city was built as the district Office of Jecheol-dong in 1973; its use was changed to a Facility for the Aged and Infants on 5 Sept. 2007 (Date of Permission: 5 Sept. 2007; Approval of use: 26 Dec. 2007), and has since been used as the nursing home for the Aged since March 2008. The nursing home has leased its office free of charge for 10 years from Pohang-si; it has 36 persons including 27 members and 8 social workers.
○ Facility layout
- Approval of use: 26 Dec. 2007
- Total building floor area: 387.42 m$^{2}$
| first floor | second floor | |
|---|---|---|
| Area (m²) | 197.32 | 190.1 |
| Use | 2 Dorm rooms for the aged, 1 Office, 1 Storage, 1 Restroom, 1 Boiler room, and Hall | 5 Dorm rooms for the aged, 1 Restroom, and Hall |
III The fire
○ Staff response, Fire department Notification and response
Upon the outbreak of fire, Ms. OO(social worker), who was sleeping in the hall on the first floor, woke up because of the smell of smoke and found fire and smoke in the office. She then asked the guard of nearby POSCO Institute of Technology (about 50m from the Indeok nursing home) to report the fire, came back to the nursing home, and rescued one elder who had woken up. She tried to go into the building again, but could not do so because of heavy smoke. Thus, she waited for the firefighters instead. After Ms. Choi's report, the guard of the POSCO Institute of Technology called a firefighter of the POSCO Institute of Technology (not the fire station); the firefighter confirmed the fire and reported to 119.
- About 04:15: Ms. OO reported the fire to the guard of the POSCO Institute of Technology.
- About 04:15: The guard reported to the fire department of the POSCO Institute of Technology.
- About 04:24: Reported to the Pohang Nambu Fire Station
- About 04:29: The advance team arrived.
- About 04:40: Suppressed the fire
- About 04:54: Extinguished the fire completely
- It took nine minutes for Ms. OO to report to the guard of the POSCO Institute of Technology and for the Pohang Nambu Fire Station to be informed.
- Distance from the Pohang Nambu Fire Station to the Indeok nursing home for the Aged: About 2.8km
- Cause and Origin
When the advance team of the Pohang Nambu Fire Station arrived at the scene of fire at 04:29, the flames were not that big, and a great deal of black smoke was being emitted from the entrance in the front of the building.
The fire broke out around the panel board (one at the top and the other one at the bottom) installed in the opposite direction diagonally from the
door of the office on the first floor and burned the office on the first floor and the ceiling and the upper wall in the main hall. A great deal of toxic smoke coming from the chairs and wooden structure in the office permeated the dorm room on the first floor through the main hall.
There were minimal traces of burn in the dorm room on the first floor, but the ceiling and wall got very sooty.
There was nothing to report with regard to the point of ignition or cause of ignition in other areas except the inner panel board in the office on the first floor.
〔图〕Point of ignitionFirst dorm roomRest room and utility roomDead:6Survivor: 1Second dorm roomDead:4Stairs to the 2nd flooO
Facility layout
〔图〕8\n
Fig 1. Front of the nursing home
〔图〕插图
Fig 2. the back and on the right
〔图〕Office\n
Fig 3. Fire scene of the office on the first floor
〔图〕插图
Fig 4. Fire scene of the entrance on the first floor
〔图〕插图
Fig 5. Office on the first floor, panel board combustion
〔图〕插图
Fig 6. Office on the first floor, entrance
〔图〕插图
Fig 7. Fire scene around the panel board in the office (The mark is the position of the panel board.)
Fig 8. Fire scene of the conductor entrance of the panel board (suspicious ignition point)
Fire growth and Spread
The Indeok nursing home for the Aged was constructed with steel-concrete slabs and is a two-story building. The fire broke out in the panel board in the office on the first floor, burned down the office furniture (desks, bookshelves, chairs, etc.), and spread outside. The burning of the main hall was not severe, however.
Two dorm rooms on the first floor had no traces of burn; one window was destroyed, and the top, wall, and bedding were scorched.
The first floor and the second floor were divided by the fire door installed in the entrance toward the second floor from the hallway on the first floor. During the fire, the fire door was closed; thus, the toxic smoke and soot that spread into the living room on the second floor was minimal.
〔图〕Entranceto theoutside\n
Fig 9. Around the entrance of the first dorm room on the first floor
〔图〕插图
Fig 10. Inside of the first dorm room on the first floor
〔图〕插图
Fig 11. Aaround the entrance of the second dorm room on the first floor
〔图〕插图
Fig 12. Inside of the second dorm room on the first floor
〔图〕插图
Fig 13. Hallway to the first floor and the second floor
〔图〕0\n
Fig 14. Around the door to the hallway on the first floor
〔图〕插图
Fig 15. Around the dorm room on the second floor
〔图〕插图
Fig 16. Dorm room main hall on the second floor
○ Evacuation routes
There are two entrances at the front (one at the center, the other on the left) on the first floor, one entrance connecting to the outside through the storage at the back, and one entrance at the stairs on the second floor. Actually, there was only one available entrance at the center of the building front -- the left entrance was located toward the hallway, and there was no exit light in the entrance at the back. Since there were two more doors to the outside, it was an obstacle to evacuation.
Though there was a door (made of aluminum poles) between the stairs to the first floor and the hallway on the second floor, it was designed to close at the stairs on the first floor. Thus, it could serve as an obstacle to evacuation, too, during a fire.
〔图〕2!L2\n
Fig 17. Two entrances at the front.
〔图〕插图
Fig 18. One entrance at the back of the building
〔图〕销联\n
Fig 19. Left entrance at the front of the building
〔图〕插图
Fig 20. Switchgear of the left entrance at the front
〔图〕*\n
Fig 21. Door at the stairs to the first Fig 22. Designed to open and close floor from the second floor on the stairs on the first floor
〔图〕插图
IV Casualties & Damage
A total of 27 elderly persons including serious dementia and stroke patients who cannot move well had lived in the Indeok nursing home for the Aged. In particular, the first floor was for the invalid.
11 elderly persons were sleeping on the first floor, and 10 of them died. The cause of death was suffocation by toxic smoke. There were 16 persons sleeping on the second floor, but no one was hurt.
IV Discussion
O Delayed initial report
It took nine minutes for Ms. Choi to report the fire to the security office of nearby POSCO Institute of Technology (about 4:15 AM) and for the district fire station to be informed accordingly. When the district Pohang Nambu firefighters arrived at the scene of fire, it was about 04:29 AM, which was about 15~20 minutes later. If the fire was reported directly to the fire station, about 9 minutes could be saved and more lives could be rescued.
Therefore, the social workers working for this kind of facility should have safety consciousness, and they should be trained to act properly in case of fire.
○ Lack of staff
During the fire, because there was just one staff in the facility, it was not possible to evacuate the 27 elderly persons with serious dementia and stroke. Therefore, there should be some kind of system such as the Automatic Notification to fire station in this kind of facility -- including the nursing home - that reports a fire to the district fire station rapidly.
○ Incomplete fire protection system
The current fire code requires that sprinklers be installed in buildings with total floor area of 600 m$^{2}$ or more in this occupancy. In the case of the Indeok nursing home for the Aged, installing the alarm system such as the Automatic Fire Detection System and Emergency Alarm System was not mandatory. If the automatic extinguishing system including sprinklers had been managed properly, the number of casualties might have been smaller. Therefore, the installation of the automatic extinguishing system including sprinklers should be considered because aged men/women would have great difficulty evacuating in case of fire.
○ Insufficient means of egress
During the fire, only the main entrance at the front was available for evacuating from the Indeok nursing home for the Aged. Because the latching device of the left entrance at the front was installed on the upper side of the door, if people on the second floor had come down to the first floor, they would not have been able to evacuate the building. Because, on the stairs between the first floor and the second floor, the latching device was installed in the door that can open and close on the first floor stairs, it could serve as an obstacle to evacuate. Therefore, the door in the emergency exit should be designed and managed to open easily.
FIRE INVESTIGATION REPORT
Fire in a high-rise complex residential building
Fire in a high-rise complex residential building
General Information
○ Location: Marine City (U-dong), Haeundae-gu, Busan
○ Date and time of Fire: 11:23 AM, 1 Oct. 2010, Friday
○ Date and time of report: 11:33:43 AM, 1 Oct. 2010
○ Casualty: 7 persons (3 residents, 1 firefighter, and 3 residents in the neighboring shopping district (minor injuries))
○ Direct Property damage: Burnt area 2800.61 m $^{2}$, KRW 5,769,729,000
○ Room of ignition: Dressing room for men on the pit level (between the third floor and the fourth floor)
○ Point of origin: Around the electrical outlet in front of the door.
○ Ignition source: Burning of unknown materials by electric spark around the outlet (suspicious)
II Building detail
Date of completion: Dec. 2005
Floors: 38 stories aboveground, 4 stories underground
Total building floor area: 68,917.26 m $^{2}$, one building
Occupancy: Basement garage, business use on the 1st~3rd floors aboveground, condominium on the 4th~37th floors (two towers)
Structure: SCR
Height: 140 m
III | Fire
- Fire department Notification and response
At 11:34 AM on 1 Oct, a dustman heard “thud” sounds and saw a blaze near the supervisor’s office while segregating garbage in the recycling area of the pit level. He reported to his fellow workers, tried to extinguish the fire, but left the site rapidly. According to the on-the-spot survey, the recycling area in the pit level and the entrance to the supervisor’s office were razed by the fire. Thus, these places were considered to be the point of initial ignition. The fan, vacuum cleaner, and floor cleaner around the entrance of the supervisor’s office burned down. According to Mr. OO (dustman), power cords were plugged in a 4-hole outlet. Based on several circumstances, a electrical fault is suspicious.
○ Time line
〔图〕Haeundae Fire StationShoppingcenter\n
Fig 1. The building and Haeundae Fire Station
| 11:21 | Fire occurred (reported by a citizen) |
|---|---|
| 11:33 | Reported to 119(fire department) |
| 11:36 | The response team of the fire department arrived at the scene of fire. |
| 11:44 | Started evacuation and lifesaving by the firefighters |
| 12:10 | Rescued 10 persons by ladder truck |
| 13:00 | Rescued 9 evacuees on the rooftop by helicopter |
| 13:02 | Extinguished the origin of fire |
| 18:48 | Extinguished completely |
- Fire growth, spread and extinguishment
① The fire occurred inside of the pit level.
② The fire spread to the outer wall through the windows.
③ The fire spread to the rooftop in 21 minutes along the inflammable aluminum panel due to the strong wind, and some residential units on the 37th floor burned down.
④ The big fire was brought under control after 2 PM.
⑤ At 3 PM, a small fire occurred again.
⑥ About 6:49 PM, the fire was extinguished completely.
- Details of fire spread
The fire started in the pit level, stayed on the outer wall aluminum panels, and continued spreading upward forming a “V”-shape vertically along the outer walls of the twin tower. The thermal insulator of the aluminum panel around the outer wall was believed to have spread the fire upward.
The outer wall was made of aluminum composite panel, and its core material was polyethylene. Therefore, when the outer panel was exposed to high-temperature thermal current (including flames), the temperature rose. This melted the aluminum on the surface of the panel, the core material of the panel started to be pyrolyzed, and flammable gas was generated. During combustion, high-temperature gas was spread to the upper side of the outer wall, and the aluminum and polyethylene melted. As a result, the fire spread from the 4th floor--the origin of fire--to the 38th floor rapidly in 20 minutes.
The reasons the fire spread so rapidly were the strong wind from the sea and the shape of the outer wall of the building.
Because the face of the outer wall receded by “-”-shape, when the thermal current moved upward, the descent of temperature was relatively slow compared to the open area, and the upper side of the high-temperature area tended to expand. Moreover, the radiant heat transfer surged because the “-”-shaped faces were opposite each other. For these various reasons, the fire spread rapidly.
○ Suppression and evacuation
Total labor involved: 668 persons (firefighters: 170; volunteer firefighters: 90; police: 350; others: 58)
60 fire engines, 2 extension ladders, 12 breakdown vans, 15 ambulances, and 5 helicopters
Rescued persons: 37
Evacuated persons: 80
IV Casualties & Damage
The burnt area inside the building was 1,134 m$^{2}$, and the outer wall from the 4th to the 38th floor burned down. Four persons sustained minor injuries, and the damage was pegged at KRW 769,729,000.
〔图〕插图
fig. 2
fig 3
Fig. 2, 3 At 12:07, the emergency bridge burned down, and the fire spread upward. (The emergency bridge was damaged, and fragments of glass and outer wall aluminum panel fell to the lower floors.)
〔图〕插图
Damaged outer wall on the top
〔图〕插图
Damaged ignition point and outer wall
Fig. 4 Damage
IV Discussion
1. Problems
Using combustible outer wall panels
There is no restriction on using combustible materials for outer walls in Korea. Thus, such kind of panel could be used. Because the aluminum panel used on this building had small weight and good processability, when applied to high-rise building, it has benefits in terms of weight and cost. The figure below shows the structure, which is fixed to the concrete wall.
〔图〕Clear coating 3.2~25umprotection filmCoating 5~10μmPrimer 4.5~10umAluminum sheet 0.3~1.0mmService coatingPrimer 4.5~10μm
Fig. 5 The configuration of Aluminum panel structure
As shown in Fig. 5, core material is inflammable polyester and is coated with aluminum and others for aesthetics, strength, and weather resistance. Because these aluminum sheet and coatings are thin, and the melting point of aluminum is about 660 °C, this panel is not fire-resistant. Moreover, because it has high thermal conductivity, the ignition temperature of polyethylene is 350~400 °C. In other words, it ignites easily with exterior heat and burns.
Over 80% of Korea's high-rise buildings are estimated to have these kinds of combustible materials.
〔图〕Panel fastner6EA/M2TH4 compound paneM12 SETinsulation anchor bol(glass wool75x80x5Tx100LGsteel brackerconcrete&ALC waln
Fig. 6 The configuration of the Outer wall cross-section
Difficulty in evacuation and rescue
For this fire, because buildings with less than 50 stories had not been classified as super high-rise building, there was no need to secure the refuge area in a middle floor as of the building code 2010. Thus, ladder trucks could not access the 16th~49th floors. In this case, fortunately, the casualties and damage were small, and some people on the top floor were rescued by a helicopter. The higher the building is, the more load on the body due to the prolonged distance for evacuation. Therefore, installation of an emergency elevator could be considered for evacuation.
Management
The original use for the pit level is for electrical equipment and machines. Thus, the requirement for the firefighting equipments was eased. Since this space was used as garbage recycling area, the load of combustibles and risk elements by humans increased, which led to the fire. Furthermore, the fire was recognized too late, and the initial response was inadequate.
Firefighting
Structurally, it was not possible to enter the pit level from the emergency stairs because of the building structure modification; there was also no fire protection water supply on the top floor. Neither was the emergency elevator available for firefighting.
2. Improvement
Supplementing related fire & building code
① Making the use of incombustible materials as finishing materials for the high-rise building compulsory
② Securing the refuge area floor for buildings with 31~50 stories
③ Making the installation of a fire protection system in the pit level compulsory
Intensifying the firefighting procedures
① Training on how to use the helicopter and ladder truck, training on adapting to the local circumstances
② Evacuation training and training on extinguishing fire in the early stage
③ Intensifying the residents' training and preventive action: Safety check on high-rise building, training on how to use the fire extinguisher, fire safety education
Appendix
Fire Loss in the Republic of Korea, 1948-2010
| Year | NO. of fires | Casualty | Death | Injury | Property loss |
|---|---|---|---|---|---|
| 1948 | 1,928 | 1,542 | 659 | 883 | 88 |
| 1949 | 4,286 | 782 | 352 | 430 | 79 |
| 1950 | 730 | 413 | 157 | 256 | 45 |
| 1951 | 1,553 | 414 | 124 | 290 | 565 |
| 1952 | 2,566 | 684 | 177 | 507 | 965 |
| 1953 | 2,453 | 610 | 136 | 474 | 19,827 |
| 1954 | 2,286 | 507 | 168 | 339 | 1,716 |
| 1955 | 1,332 | 440 | 149 | 291 | 685 |
| 1956 | 1,341 | 278 | 109 | 169 | 1,303 |
| 1957 | 1,150 | 320 | 146 | 174 | 1,568 |
| 1958 | 1,547 | 292 | 112 | 180 | 1,708 |
| 1959 | 1,558 | 321 | 143 | 178 | 1,619 |
| 1960 | 1,946 | 467 | 180 | 287 | 9,391 |
| 1961 | 2,355 | 397 | 122 | 275 | 2,254 |
| 1962 | 2,174 | 487 | 150 | 337 | 212 |
| 1963 | 1,904 | 303 | 103 | 200 | 321 |
| 1964 | 2,617 | 544 | 154 | 390 | 297 |
| 1965 | 3,141 | 468 | 143 | 325 | 799 |
| 1966 | 3,077 | 508 | 165 | 343 | 521 |
| 1967 | 3,482 | 716 | 226 | 490 | 831 |
| 1968 | 3,909 | 774 | 198 | 576 | 1,513 |
| 1969 | 4,181 | 1,010 | 201 | 809 | 1,556 |
| 1970 | 4,969 | 1,124 | 294 | 830 | 2,063 |
| 1971 | 4,412 | 1,112 | 354 | 758 | 2,186 |
| 1972 | 3,749 | 1,119 | 259 | 860 | 1,621 |
| 1973 | 4,159 | 1,058 | 245 | 813 | 1,539 |
| 1974 | 3,901 | 1,125 | 284 | 841 | 16,865 |
| 1975 | 4,259 | 929 | 219 | 710 | 6,064 |
| 1976 | 4,712 | 884 | 221 | 663 | 8,376 |
| 1977 | 5,363 | 1,059 | 259 | 800 | 4,457 |
| 1978 | 5,648 | 1,080 | 236 | 844 | 8,454 |
| Year | NO. of fires | Casualty | Death | Injury | Property loss |
|---|---|---|---|---|---|
| 1979 | 5,711 | 1,097 | 283 | 814 | 8,851 |
| 1980 | 5,438 | 888 | 247 | 641 | 8,262 |
| 1981 | 5,851 | 999 | 291 | 708 | 13,248 |
| 1982 | 6,822 | 971 | 276 | 695 | 13,153 |
| 1983 | 7,725 | 654 | 381 | 273 | 12,843 |
| 1984 | 8,562 | 1,331 | 372 | 959 | 13,844 |
| 1985 | 8,137 | 1,080 | 260 | 820 | 15,409 |
| 1986 | 8,453 | 1,188 | 306 | 882 | 11,375 |
| 1987 | 10,144 | 1,474 | 321 | 1,153 | 14,880 |
| 1988 | 12,507 | 1,550 | 414 | 1,136 | 34,783 |
| 1989 | 12,704 | 1,519 | 447 | 1,072 | 22,357 |
| 1990 | 14,249 | 1,548 | 348 | 1,200 | 34,133 |
| 1991 | 16,487 | 1,781 | 525 | 1,256 | 44,218 |
| 1992 | 17,458 | 1,747 | 510 | 1,237 | 52,675 |
| 1993 | 18,747 | 1,777 | 573 | 1,204 | 51,890 |
| 1994 | 22,043 | 1,879 | 555 | 1,324 | 132,624 |
| 1995 | 26,071 | 2,219 | 571 | 1,648 | 100,746 |
| 1996 | 28,665 | 2,223 | 589 | 1,634 | 113,147 |
| 1997 | 29,472 | 2,195 | 564 | 1,631 | 121,712 |
| 1998 | 32,664 | 2,284 | 505 | 1,779 | 159,721 |
| 1999 | 33,856 | 2,370 | 545 | 1,825 | 166,426 |
| 2000 | 34,844 | 2,384 | 531 | 1,853 | 151,972 |
| 2001 | 36,169 | 2,376 | 516 | 1,860 | 169,750 |
| 2002 | 32,966 | 2,235 | 491 | 1,744 | 143,447 |
| 2003 | 31,272 | 2,833 | 744 | 2,089 | 151,590 |
| 2004 | 32,737 | 2,304 | 484 | 1,820 | 146,634 |
| 2005 | 32,340 | 2,342 | 505 | 1,837 | 171,374 |
| 2006 | 31,778 | 2,180 | 446 | 1,734 | 150,792 |
| 2007 | 49,318 | 2,459 | 424 | 2,035 | 248,417 |
| 2008 | 49,318 | 2,716 | 468 | 2,248 | 383,142 |
| 2009 | 47,318 | 2,444 | 409 | 2,035 | 251,852 |
| 2010 | 41,863 | 1,892 | 304 | 1,588 | 266,776 |
This is published as the Agreement of Cooperation between KFPA and NFPA. Please feel free to contact Research & investigation team of KFPA if you have any inquires. (E-Mail hryu@kfpa.or.kr, Tel 82-2-3780-0322, Fax 82-2-3780-0329)
〔图〕530939788988874967\n
ISBN 978-89-88874-96-7
2010 KOREAN FIRE DATA
Published in December 2011
Edited by Research & Investigation Team
Published by Korean Fire Protection Association
35-4 Yeouido-Dong, Yeungdeungpo-Gu
Seoul 150-885, KOREA, Republic of
TEL 82-2-3780-0200
FAX 82-2-3780-0329
E-Mail k f pa @ k f pa . or . k r / /
http://www.kfpa.or.kr
Registered No. 13-794 (1997.8.14)
Printed by
ISBN 978-89-88874-96-7 93530